MODEL | FLOW RATE SCFM1 |
FLOW RATE NM3/H |
VOLTAGES2
V/ph/Hz |
POWER3
KW |
INLET/OUTLET CONNECTIONS4 |
---|---|---|---|---|---|
HPRP2500 | 2500 | 4248 | Standard: 380-420/3/50 460/3/60 Optional: |
15.03 | 6” FLG |
HPRP3000 | 3000 | 5097 | 19.61 | 6” FLG |
Dryers meet agency approvals: CSA (CAN/CSA-C22.2 No.236-05) – Heating and Cooling Equipment and UL Standard No.1995.
HFC refrigerants: R-404a
1 Dryer flow ratings are in accordance with ISO 7183 (option A2) conditions: inlet air at 100 psig (7 barg) and 100°F (38°C) saturated, ambient air at 100°F (38°C), operating on 60 Hz power supply.
2 Optional Voltages: 575/3/60 models utilize mounted transformers to step-down incoming power to 460/3/60; 230/3/60 models utilize mounted transformers to step-up to 460/3/60.
3 Full flow kW value operating on 460/3/60 Hz power supply.
4 DIN Flanges available.
Flow scfm |
Maximum Working Pressure |
Minimum Working Pressure |
Maximum Inlet Air Temperature |
Minimum Inlet Air Temperature |
Maximum Ambient Air Temperature |
Minimum Ambient Air Temperature |
||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
scfm | psig | barg | psig | barg | °F | °C | °F | °C | °F | °C | °F | °C |
2500-3000 | 232 | 16 | 30 | 2 | 130 | 54 | 40 | 4 | 110 | 43 | 40 | 4 |